Sterility assurance in just 15 minutes.*
Fill out the form to download the STERRAD® VELOCITY® Factsheet.
Fill out the form to learn how to initiate an upgrade or purchase a STERRAD® VELOCITY® System.
Fill out the form to learn how to initiate an upgrade or purchase a STERRAD® VELOCITY® System.
Fill out the form to learn how to initiate an upgrade or purchase a STERRAD® VELOCITY® System.
© ASP 2020. All rights reserved. AD-200034-01-CT_A
Reduce infection risks by releasing your instrument load in just 15'
Enhance compliance to reprocessing guidelines.
Use a Process Challenge Device in every cycle
15 minutes* compared to 24 hours allows you to release your load only after you have received the Bl outcome and not before, meeting the requirements of demanding OR schedules.
More and more global standards** recommend using biological indicators in every cycle to ensure necessary conditions are met to achieve sterilization. Combined with parametric release and IMS, challenging the sterilization process in every cycle creates the ultimate possible control currently available in Low Temperature Sterilization.
Biological Indicators and Process Challenge Devices represent different levels of challenge in the sterilization process. Biological Indicators are intended to demonstrate whether the conditions were adequate
to achieve sterilization.
*Fastest BI/PCD currently marketed for STERRAD® Sterilization Systems. 15 or 30 minutes to result dependent on the software version on the STERRAD Velocity® Reader. 15 minutes to result for SW version 1139260410 or greater; 30 minutes to result for SW version 1139260317 or below.
† Automated integration of information requires connection to ASP ACCESS™ Technology
†† Comparison to Steris® Celerity™ HP 20 (20 mins) and 3M™ Attest™ (24 mins).
The third-party trademarks used herein are the properties of their respective owners.
Capitalized product names are trademarks of Advanced Sterilization Products, Inc.
Important information: Prior to use, refer to the instructions for use supplied with this device for indications, contraindications, side effects, warnings and precautions.
ASP International GmbH
Gubelstrasse 34, Zug 6300, Switzerland
Automated correlation† of STERRAD® cycle and BI records remotely accessible
Automated record keeping allows CSSDs to demonstrate process compliance and audit readiness, anytime, reducing the risk of liability.
Easy to Use
With integrated scanner and connecting printer, enabling quick & easy BI processing & documentation.
Process Challenge Devices provide a challenge to the sterilization process that
is equal to or greater than the worst-case medical device loads routinely processed. BIs, in general, do not have the requirement to represent worst-case devices per ISO 11138 and FDA guidance.
Now, STERRAD® VELOCITY™ is both a Biological Indicator as well as a Process Challenge Device, elevating the sterilization process monitoring standard
Now, STERRAD® VELOCITY™ is both a Biological Indicator as well as a Process Challenge Device, elevating the sterilization process monitoring standard